Product Price :Get Latest Price

Product Details:

Current Consumptionmax 9 A
Display Range-60 mmhg to 520 mmgh
Accuracy+/- 10 mmhg
Weight80 kg (Approx)
Water Inlet Temperature5-30dig C
Resolution20 mmhg
Dimensions1330 x 495 x 340 mm
Inlet Pressure1 .5 - 6.0 bar
Power Supply230 V - 10 % A, 50 Hz

Fresenius Dialysis Machine has been developed to provide safety and efficiency for all important treatment moralities within the scope of renal replacement therapies.

This Includes:
  • Bicarbonate or acetate dialysis
  • Single-needle or single-needle click-clack
  • Isolated ultra-filtration

The automated acquisition, monitoring and control of specific patient and machine parameters with the 4008B hemodialysis machine provide the operator with continuous and precise assessment of the current treatment situation.

Key features of the 4008B hemodialysis machine include:
  • Treatment with ultra-pure dialysis fluid (DIASAFE®plus filter)
  • Use of hygienic, dry bicarbonate concentrate (Bibag®)
  • Connection for central concentrate supply

 

In addition, the following therapeutic tools are available:

  • Blood pressure monitor (BPM)
  • Easy data management with patient card (offline) or network integration (online)

 

Specifications:

  • Dimensions: 1330 x 495 x 340 mm
  • Weight: approx. 80 kg

 

Water Supply:

  • Inlet Pressure: 1 .5—6.0 bar
  • Water Inlet Temperature: 5-30dig C

 

Electrical Data:

  • Power Supply: 230 v - 10 % A, 50 Hz
  • Current Consumption: max 9 A

 

Venous Pressure Monitoring:

  • Display Range: -60 mmhg to 520 mmgh
  • Accuracy: +/- 10 mmhg
  • Resolution: 20 mmhg

 

Trans Membrane Pressure:

  • Display range: -60 mmhg to + 500 mmhg
  • Resolution: 20 mmhg

 

Arterial Blood Pump:

  • Blood Flow Range: 10-600 ml/min
  • Accuracy: +/- 10%
  • Air Bubble Detector: By ultra sound transmission,
  • Additional optical monitoring

 

Heparin Pump:

  • Delivery Range: 0 to 10 ml
  • Bolus Function: max 5 ml per bolus
  • Syringe Size: 20 ml, 30 ml and 5O ml

 

Dialysate Fluid Circuit:

  • Selectable: 0 – 300 - 500 ml/min
  • Dialysate Fluid Temperature: Selectable: 35-390 C

 

Dialysate Fluid Conductivity:

  • Range: 12.8 to 15.7 ms/cm. accuracy : +/- 0.1 ms/cm

 

Sodium Concentration Dialysis Fluid:

  • Default Mixing Ratio: 1 + 34
  • Range: - 13 to +13 mmol/bicarbonate

 

Bicarbonate Concentration:

  • Default Mixing Ratio: 1 + 27.6
  • Range: - 8 to + 8 mmol/l bicarbonate
  • Balancing Accuracy: +/- 0.1 % of the dialysate flow

 

Ultra Filtration:

  • UF Rate: 0 to 4 lph
  • Accuracy: =/- o.5%
  • Allowed Dialyser UF Factor: unlimited
  • Parameter Displayed: uf goal/uf time/uf rate/uf volume
  • Blood Leak Detector: Sensitivity:

 

Disinfection and Cleaning Programs:

  • Rinse: Temperature: 370c/600 ml/min
  • Hot Rinse: Temperature: 850c/450 ml/min
  • Cleaning Sportal: Temperature: 37
Request
Callback
Yes! I am Interested
X

Explore more products

JMS Scalp Vein Set
JMS Scalp Vein Set
Get Best Quote
JMS Infusion Set
JMS Infusion Set
Get Best Quote
JMS Meditape
JMS Meditape
Get Best Quote
JMS Dialysis Machine
JMS Dialysis Machine
Get Best Quote
AV Fistula Needle
AV Fistula Needle
Get Best Quote


Reach Us
Vishal Thakkar (BDM Exports)
502, 6th Floor, Ecstasy, City Of Joy Commercial Complex JSD Road
Mulund West, Mumbai- 400080, Maharashtra, India



Call Us

Share Us

F GT L


Send E-mailSend SMS